Swirl Diffuser

thumbnail-image

Swirl Diffuser

ASTRAL Swirl Diffusers are designed to create a rotary swirling motion to the supply air discharge, which rapidly induces the room air to quickly decrease the velocity and temperature difference of the supply air.

Swirl diffusers are used for ceiling or exposed duct mounting. Specially designed for spaces where considerable temperature changes take place and with ceiling heights of more than 4m, where high comfort standards are required. It can be used for commercial (conference rooms, auditoriums, etc.) or industrial installations (industrial halls, airports, theatres, bank buildings, shopping malls, exhibition halls, etc).

Heating, Cooling or isothermal air can be supplied by an adapted air pattern. Cold air has a tendency to ‘drop’, making it advisable to spread that air horizontally. Warm air however, can remain too close to the ceiling, not reaching the occupied zone. The variable swirl diffuser M-SWD, which can handle supply temperature differences of -10K up to +15K, can solve those problems.

Rear View AS-SWD

Product Dimension

Product Code Description Neck Ø Face Ø Hole Ø Height H
AS-SWD200 Round Swirl Diffuser - 12 Blade 200 320 275 185
AS-SWD250 Round Swirl Diffuser - 12 Blade 250 365 320 185
AS-SWD315 Round Swirl Diffuser - 12 Blade 315 445 385 215
AS-SWD350 Round Swirl Diffuser - 12 Blade 350 505 445 215
AS-SWD400 Round Swirl Diffuser - 12 Blade 400 565 505 230
AS-SWD500 Round Swirl Diffuser - 12 Blade 500 720 605 260
AS-SWD630 Round Swirl Diffuser - 12 Blade 630 875 760 310

Performance Table: Swirl Diffuser

Product Code Pressure (Pa) 5 10 20 30 40 50 60 70
AS-SWD200 Flow Rate (l/s) 19294151 60677175
Noise NR <20<20<20<20 22283639
Throw 0° (m) 0.40.81.62.2 2.73.13.43.6
AS-SWD250 Flow Rate (l/s) 33507188 101114123130
Noise NR <20<20<2021 26323841
Throw 0° (m) 0.71.22.12.8 3.23.63.94.2
AS-SWD315 Flow Rate (l/s) 6689126153 175198217235
Noise NR <20<202226 30353840
Throw 0° (m) 1.11.72.73.3 3.84.24.65.1
AS-SWD350 Flow Rate (l/s) 83112155193 222249271294
Noise NR <20<202131 35394042
Throw 0° (m) 1.21.92.93.6 4.14.65.15.6
AS-SWD400 Flow Rate (l/s) 105151210257 293330363392
Noise NR <20<202229 32363942
Throw 0° (m) 1.32.03.13.7 4.34.85.45.9
AS-SWD500 Flow Rate (l/s) 142222347423 472527583638
Noise NR <20253235 37394143
Throw 0° (m) 1.83.544.5 5.278.112
AS-SWD630 Flow Rate (l/s) 175256412505 6107158701100
Noise NR <20263437 40444752
Throw 0° (m) 2.33.84.17 11131518

Installation: Swirl Diffuser with Plenum Box

Swirl Diffuser Adjustable

Increasingly stringent requirements from the standpoint of technical features (higher supply flow rates and lower velocities in the occupant area) and aesthetics (smoother incorporation in the interior design) have generally made swirl diffusers a better choice for air diffusion. The recommended mounting height is around 2.5 to 4.0m for all models. All these ASTRAL units can be used in VAV systems, allowing the flow rate to be reduced up to 25% of the nominal air flow rate without producing uncomfortable air currents in the facility.

Front Face

Back Face

Front Face

Face Size (A) No. of Blade
595 x 595 mm 16
595 x 595 mm 24
595 x 595 mm 48

Performance Table: Fixed Vane with Air Stream between Diffusers

Flow rate No. of slots 16 24 32 36 40 48
(m³/h) (l/s) B 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7

Symbols:

Performance Table: Fixed Vane with Air Stream towards the wall

Flow rate No. of slots 16 20 24 32 36 40 48
(m³/h) (l/s) B 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7 1.21.82.7

Symbols:

Fixed Vane Swirl Diffuser with number of deflectors

400/16

600/36

400/16

400/16

500/20

600/40

500/20

500/20

600/16

600/48

600/36

600/36

600/20

825/60

600/48

600/48

300/9

500/24

600/32

Fixed Blades Swirl Diffuser

AS-SW-F

AS-SW-F

Front Face

Back Face

Face Size ( A ) No. of Blade
595 x 595 mm 34

Performance Table: Fixed Blade

Inlet Size 6"
Neck Velocity 300 400 500 600 700 800 900 1000
VP 0.0060.010.0160.022 0.0310.040.050.062
Total Pressure 0.010.0180.0280.04 0.0540.0710.090.111
CFM 597998118 137157177196
NC (dB) –––– 20232528
Throw (ft) 1-1-21-1-21-1-31-2-4 1-2-42-2-52-3-52-3-6
Inlet Size 8"
Neck Velocity 300 400 500 600 700 800 900 1000
VP 0.0060.010.0160.022 0.0310.040.050.062
Total Pressure 0.0170.030.0470.068 0.0920.120.1520.188
CFM 105140174209 244279314349
NC (dB) –––19 22252830
Throw (ft) 1-2-31-2-42-3-52-3-6 2-4-73-4-73-5-83-5-8
Inlet Size 12"
Neck Velocity 300 400 500 600 700 800 900 1000
VP 0.0060.010.0160.022 0.0310.040.050.062
Total Pressure 0.0480.0860.1340.194 0.2640.3440.4360.538
CFM 236314393471 550628707785
NC (dB) ––1923 26293234
Throw (ft) 2-4-73-5-84-6-85-7-9 5-7-106-8-117-8-117-8-12
Inlet Size 14"
Neck Velocity 300 400 500 600 700 800 900 1000
VP 0.006 0.01 0.016 0.022 0.031 0.04 0.052 0.064
Total Pressure 0.082 0.146 0.228 0.328 0.446 0.583 0.748 0.912
CFM 321 428 535 641 748 855 962 1070
NC (dB) – – 20 24 27 30 33 35
Throw (ft) 3-5-8 4-6-9 5-7-10 6-8-11 7-8-12 7-9-12 8-10-13 9-11-14
Inlet Size 16"
Neck Velocity 300 400 500 600 700 800
VP 0.006 0.01 0.016 0.022 0.032 0.04
Total Pressure 0.139 0.247 0.385 0.555 0.772 0.988
CFM 419 558 698 837 978 1118
NC (dB) – – 21 25 28 31
Throw (ft) 4-6-9 6-7-10 6-8-11 7-9-12 7-10-13 8-11-14

Performance Notes: